Side-Power 8980 Installation Manual Page 14

  • Download
  • Add to my manuals
  • Print
  • Page
    / 28
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 13
14
LOCATION 120-121: PROGRAMMING TO REPORT AC POWER LOSS
The Ranger 8980 has the ability to report an AC power failure code when AC power is lost. This report can be
immediate, or delayed depending on the information programmed in location 150 (AC Power Loss Delay). The desired
AC failure mode should be programmed in locations 120-121. If both locations are "0", AC power failures will not be
reported. Location 120 contains the standard digit, and location 121 contains the extended digit. When using 4+2
format, the number programmed in location 120 is sent as the "ones" digit. The "tens" digit is programmed in location
121.
LOCATION 122-123: PROGRAMMING TO REPORT LOW BATTERY
The Ranger 8980 has the ability to report a low battery code when AC power has been lost and the battery has
discharged down to 10.3 volts. The desired low battery code is programmed in locations 122-123. If both locations are
"0", low battery will not be reported. Location 122 contains the standard digit, and location 123 contains the extended
digit. When using 4+2 format, the number programmed in location 122 is sent as the "ones" digit. The "tens" digit is
programmed in location 123.
LOCATION 124: PROGRAMMING FOR PRIORITY ZONE TROUBLE REPORTING
The Ranger 8980 has the ability to report a trouble code each time a Priority zone opens. The desired trouble code is
programmed in location 124. If this location contains a "0", the Priority Trouble will not be reported.
LOCATION 125: PROGRAMMING FOR ZONE BYPASS REPORTING
The Ranger 8980 has the ability to report a bypass on zones 1-8. The desired bypass code is programmed in location
125. If this location contains a "0", zone bypass will not be reported. When using 4+2 format, the number programmed
in this location is sent as the "tens" digit. The "ones" digit is the zone communicator code. The bypass will be reported
at the end of the exit delay for non-24 hour zones. 24 hour zones will report a bypass immediately. When a bypass is
removed, a restore will be reported if "Restore" is enabled in location 126.
LOCATION 126: PROGRAMMING THE COMMUNICATOR CODE FOR RESTORAL
Location 126 contains the communicator code that will be sent for restoral of a zone. If this location contains a "0", no
restorals will be reported. If a restoral code is programmed and an extended format is selected, the restorals will be
reported by zone. If a restoral code is programmed and an extended format is not selected, a restoral code will be sent
when all of the previously reported conditions have restored. When using 4+2 format, the number programmed in this
location is sent as the first, or "tens" digit. The second, or "ones" digit will be the "ones" digit of the zone or condition
that restored.
LOCATION 127: PROGRAMMING THE COMMUNICATOR CODE FOR CANCEL (EXCEPTION OPENING)
Location 127 contains the communicator code that will be sent for cancel. The cancel code programmed in this
location will be sent if an arm/disarm code is entered after a trip on zones 1 through 8 has been reported (excluding 24
hour zones). After a cancel has been reported, no loop restorals will be transmitted on non-24 Hour zones. If this
location contains a "0", cancel is disabled. When using 4+2 format, the number programmed in this location is sent as
the "tens" digit. The "ones" digit is the man number of the person that cancelled. When using a remote arming input,
the man number is 1.
LOCATION 128: PROGRAMMING THE COMMUNICATOR TO ABORT
Location 128 is used to enable the communicator abort. A "1" in this location will cause the Ranger 8980 to abort the
report of a trip on any non-24 hour zone, if an arm/disarm code is entered prior to central station connection. If this
location contains a "0", the Ranger 8980 will not abort any reports.
LOCATION 129: PROGRAMMING FOR SILENT PANIC/HOLD-UP
Location 129 is used to silence the audible output for a panic/hold-up alarm. Programming a "1" in this location will
silence the audible output during a panic/hold-up alarm. If this location contains a "0", the Ranger 8980 will have an
audible panic/hold-up output.
Page view 13
1 2 ... 9 10 11 12 13 14 15 16 17 18 19 ... 27 28

Comments to this Manuals

No comments