RANGER 8980 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS TABLE OF CONTENTS
10 LOCATIONS 000-003: PROGRAMMING THE MASTER ARM/DISARM CODE Locations 000-003 contain master arm/disarm code (user number 1). Location 000 conta
11 LOCATIONS 078-085: PROGRAMMING THE ZONE TYPES Locations 078 through 085 contain a number identifying the characteristics of each of the 8 zones
12 LOCATION 090-091: PROGRAMMING FOR AUXILIARY 2, [4] & [6] DOUBLE KEYPRESS The Ranger 8980 has the ability to report an Auxiliary 2 code and
13 LOCATION 103: PROGRAMMING TO REPORT OPENINGS The Ranger 8980 has the ability to report an opening code each time the control is disarmed.
14 LOCATION 120-121: PROGRAMMING TO REPORT AC POWER LOSS The Ranger 8980 has the ability to report an AC power failure code when AC power is lost
15 LOCATION 130: ENABLING THE SWINGER SHUTDOWN Location 130 is used to enable the burglary zone swinger shutdown. The number programmed in this lo
16 LOCATION 138: NO ARMING WITH A ZONE BYPASSED If a "1" is programmed in location 138, the Ranger 8980 will not arm with any zone bypa
17 LOCATION 145-148: PROGRAMMING THE AUXILIARY OUTPUTS Four of the functions in the following table are available on terminals 1 thru 4. These out
18 LOCATION 151: PROGRAMMING THE NUMBER OF RINGS TO ANSWER DOWNLOAD CALL Location 151 contains the number of rings the 8980 must detect before ans
19 LOCATION 160: PROGRAMMING THE CLOCK, CURRENT MINUTES - TENS DIGIT Location 160 contains the current minutes - tens digit. The time is entered
2 RANGER 8980 INSTALLATION MANUAL General Description The Caddx Ranger 8980 is a versatile 8 zone up/downloadable security control with a built
20 LOCATION 168-171: PROGRAMMING THE SEED CODE FOR ROTATING MAINTENANCE CODES Locations 168-171 contain the complex, or "seed code" req
21 LOCATION 175: PROGRAMMING ZONES 1,2,7, & 8 FOR NORMALLY CLOSED OPERATION ONLY Location 175 is used to program zones 1,2,7, & 8 for nor
22 LOCATION 177: SPLIT REPORTING - PROGRAMMING AC POWER FAIL, LOW BATTERY, OPEN/CLOSE, AND MAINTENANCE OPEN/CLOSE TO REPORT
23 THE FOLLOWING LOCATIONS ARE ACCESSIBLE ONLY THROUGH DOWNLOADING LOCATIONS 186-193: CONTROL PANEL ACCESS CODE Locations 186-193 contain the ei
24 ARM/DISARM CODES 1-7 LOCATION PAGE DESCRIPTION DATA 1 DATA 2 DATA 3 DATA 4 DEFAULT 000-003 10 USER #1 ARM / DISARM CODE &
25 LOCATION PAGE DESCRIPTION ZONE ID EVENT/EXT CODE DEFAULT 103 12 OPENING COMMUNICATOR CODE MAN NUMBER "0" DISABLED 104-1
26 LOCATION PAGE DESCRIPTION DATA DEFAULT 157 18 PROGRAM CLOCK, CURRENT DAY OF MONTH - ONES DIGIT UNDEFINED 158 18 PROGRAM CLOCK, C
27 LOCAL TELEPHONE COMPANY INTERFACE INFORMATION TELEPHONE CONNECTION REQUIREMENTS Except for telephone company provided ringers, all connecti
SPECIFICATIONS OPERATING POWER 16.5 VAC 25 VA Transformer AUXILIARY POWER 12 VDC 500mA LOOP RESISTANCE 300 Ohms Maximum BUILT-
3 PARTS DIAGRAM
4 TERMINAL DRAWING & SPECIAL NOTES
5 TERMINAL DESCRIPTION TERMINAL DESCRIPTION 1 Connect one side of zone 1 loop. The other side of loop to common terminal 2.
6 HOW TO PROGRAM THE 8980 The Ranger 8980 can be placed into the "Program" mode by either of the following methods. 1. Enter the 4 di
7 PROGRAMMING EXAMPLE - FIGURE 1 8950 PROGRAMMER - FIGURE 2
8 PAGES 8 & 9 DESCRIBE ALL THE LOCATIONS WHICH MUST BE PROGRAMMED FOR THE RANGER 8980 TO FUNCTION AND REPORT TO A CENTRAL STATION. OTHER OPTIO
9 LOCATION 074: PROGRAMMING COMMUNICATOR FORMAT FOR THE SECONDARY TELEPHONE NUMBER Location 074 contains the communicator format for the secondar
Comments to this Manuals